EBI 12-TC230 Conductivity Data Logger
Cat. No. : 1340-6667
|
Temperature / Pressure Data Loggers EBI 12 series
General specifications for all EBI 12-TP series |
|
Operating temperature (pressure logger) |
0 °C ... +150 °C (+32 °F ... +302 °F) |
Temperature |
|
Accuracy |
±0.1 °C (0 °C ... +120 °C) ±0.05 °C (+120 °C ... +140 °C) ±0.1 °C (+140 °C … +150 °C) |
Resolution |
0.01 °C |
Sensor |
Pt 1000, Class A |
Pressure |
|
Accuracy |
±10 mbar (50 mbar … 150 mbar) ±10 mbar (2,050 mbar … 2,250 mbar) ±10 mbar (3,000 mbar … 3,250 mbar) ±15 mbar (for the remaining measurement range) |
Resolution |
1 mbar |
Sensor |
Piezoresistive pressure sensor (temperature compensated) |
Data memory |
Max. 100,000 measurements (total) |
Sampling rate |
250 ms ... 24 |
Measurement mode |
• Endless measurement • Measure upon start time • Start immediately until end of memory • Start- / Stop measurement |
Storage temperature |
0 °C ... +125 °C (+32 °F ... +257 °F) |
Maximum operating pressure |
Pressure logger: 7 bar (abs) |
Minimum operating pressure |
Logger with flexible cable probe: 20 mbar (abs) |
Time accuracy (24h) |
< 5 sec |
Battery |
Lithium cell, 3.6 V, user replaceable |
Dimensions (Ø x H) |
48 mm x 32 mm* |
Weight |
Approximately 120 g * |
Housing material |
316 L Stainless steel / PEEK |
Protection class |
IP 68 |
Certificate |
Factory calibration certificate |
Product lines
|
Red line |
Blue line |
Short Description |
Temperature data logger with external probe less than 2 mm diameter Data logger with additional units Special process logger |
All other temperature data logger |
Radio mode |
Loggers can transfer data during the measurement process |
Not possible |
Total memory capacity |
100,000 values |
27,000 values |
Click here to download brochure
Untuk info lengkap mengenai Harga dan Stok silahkan kontak kami via Online Chat atau Contact
EBI 12-TC230 Temperature / Conductivity Data Logger 1340-6667
Conductivity measurement (Red Line)
In processes like e.g. washer disinfectors, the measurement of conductivity in the last dishwater is required.This is reasonably done in the running process without any interruption.
• 1 external temperature probe
• 1 external conductivity probe
Specification |
|
Temperature |
|
Measurement range |
0 °C ... +125 °C (+32 °F ... +257 °F) |
Accuracy |
± 0.2 °C |
Resolution |
0.01 °C |
Sensor |
Pt 1000 |
Conductivity |
|
Measurement range |
1 … 2,000 μS/cm |
Accuracy |
± 0.5 μS (1 μS/cm .. 20 μS/cm) ± 1.0 μS (20.1 μS/cm .. 100 μS/cm) ± 2.5% of measured value (100.1μS/cm ... 1500μS/cm) ± 5% from the measurement range (remaining range) |
Resolution |
0.1 μS/cm |
Sensor |
Conductivity electrode |
Data memory |
2 x 50,000 measurement values |
Measurement mode |
• Endless measurement immediately • Start / Stop measurement • Measure immediately until end of memory |
Storage temperature |
0 °C ... +125 °C (+32 °F ... +257 °F) |
Max. operating pressure (burst pressure) |
2.5 bar (abs.) |
Battery |
Lithium cell, user replaceable |
Dimensions (D x H) |
48 mm x 130 mm |
Housing material |
316 L Stainless steel / PEEK |
Protection class |
IP 68 |
Factory calibration certificate |
0 °C, +60 °C and +121 °C 5 μS/cm, 100 μS/cm, 1413 μS/cm at +25 °C |
Radio mode |