EBI 12-T22X Temperature Data Logger
Brand
Ebro
Weight
1.5 Kg
Stock
indent
Description
Technical Specification

General specifications for EBI 12 series

Operating temperature: logger

-90 °C … +150 °C (-130 °F ... 302 °F)

Operating temperature: radio operation

-30 °C … +150 °C (-22 °F ... 302 °F)

Temperature accuracy

±1.5 °C (-200 °C … -85 °C)

±0.5 °C (-85 °C … -40 °C)

±0.2 °C (-40 °C … 0 °C)

±0.1 °C (0 °C ... +120 °C)

±0.05 °C (+120 °C … +140 °C)

± 0.1 °C (+140 °C … +150 °C)

± 0.5 °C (+150 °C … +250 °C)

± 0.8 °C (+250 °C … +400 °C)

Time accuracy

< 5 sec (24 h)

Temperature resolution

0.01 °C

Sensor

Pt 1000, Class A

Interval

250 ms ... 24 hours

Measurement mode

• Endless measurement

• Start / stop measurement

• Measure upon start temperature

• Start immediately until end of memory

Storage temperature

0 °C … +125 °C

Maximum operating pressure

Temperature logger 10 bar (abs)

Minimum operating pressure

Logger with flexible cable probe 20 mbar (abs)

Battery

Lithium cell, 3.6 V, user replaceable

Dimensions (Ø x H)

48 mm x 24 mm

Weight

Approximately 110 g

Housing material

316 L Stainless steel / PEEK

Protection class

IP 68

Certificate

Factory calibration certificate

 

Product lines

 

Red line

Blue line

Short Description

Temperature data logger with external

probe less than 2 mm diameter

Data logger with additional units

Special process logger

All other temperature data logger

Radio mode

Loggers can transfer data during the

measurement process

Not possible

Total memory capacity

100,000 values

27,000 values

 

Click here to download brochure

Untuk info lengkap mengenai Harga dan Stok silahkan kontak kami via Online Chat atau Contact

EBI 12-T22X Temperature Data Logger

bendable metal probe (Red Line)

• 1 external temperature probe, Ø 1.5 mm

• Radial arranged

 

Application

• Measurement in drain of sterilizers

• In oven (protected by Thermal-Isolation-Box)

• EtO sterilization (ATEX type)

 

Specification

Measurement range

(Use in EX Area)

EBI 12-T220 : -200 °C ... +200 °C (-328 °F ...+392 °F)

EBI 12-T220-EX : -40 °C ... +85 °C (-40 °F ...+185 °F)

EBI 12-T221 : -200 °C ... +400 °C (-328 °F ... +752 °F)

Accuracy

EBI 12-T220 : ± 1,5 °C (-200 °C … -85 °C)

                       ± 0,5°C (-85 °C … -40 °C)

                       ± 0,2°C (-40 °C … 0 °C)

                       ± 0,1 °C (0 °C ... +120 °C)

                       ± 0,05 °C (+120 °C … +140 °C)

                       ± 0,1 °C (+140 °C … +150 °C)

EBI 12-T220-EX : ± 0,2°C (-40 °C … 0 °C)

                             ± 0,1 °C (0 °C ... +120 °C)

                             ± 0,05 °C (+120 °C … +140 °C)

                             ± 0,1 °C (+140 °C … +150 °C)

EBI 12-T221 : ± 1,5 °C (-200 °C … -85 °C)

                       ± 0,5°C (-85 °C … -40 °C)

                       ± 0,2°C (-40 °C … 0 °C)

                       ± 0,1 °C (0 °C ... +120 °C)

                       ± 0,05 °C (+120 °C … +140 °C)

                       ± 0,1 °C (+140 °C … +150 °C)

                       ± 0,5 °C (+150 °C …+ 250 °C)

                       ± 0,8 °C (+250 °C … +400 °C)

Data memory

100,000 measurement values

Factory calibration certificate

-20 °C, 0 °C, +60 °C, +134 °C and +250 °C if the probe length

is 500 mm

Sensor

Pt 1,000, class A

Sample Rate

250 msec ... 24 h

IP Rating

IP 68

Battery

Lithium battery (3,6 V), user replaceable

Dimensions

(Ø x H) 48 mm x 24 mm

 

 

 

Ordering Information

Type

Description

Cat. No.

EBI 12-T220

Needle length = 250 mm

1340-6604

EBI 12-T220-EX

Needle length = 250 mm

1340-6604-EX

EBI 12-T221

Needle length = 500 mm

1340-6605

Related Products
GLOBAL SCIENTIFIC INTERNATIONAL
Sentra Niaga Puri Indah Blok T3-6
Kembangan Selatan - Jakarta Barat
DKI Jakarta 11610 - Indonesia
www.gsi.id
Customer Support
Shipping and Payment Method