RFM700-M Series refractometers are robust, low cost, fully automatic instruments that are ideally suited to the food, sugar and beverage industries but can also be used in many other non-food applications where temperature control is not required, for example measuring sugar (°Brix) concentrations in the food processing industry. Robust 2-decimal 0-100 Brix refractometer for use in factory or lab.
Odering Code :
Code |
Descriptions |
19-00 |
RFM712-M refractometer with latest integral 4” full colour display, robust switch membrane and USB connectivity. Supplied with instruction manual and certificate of conformity. |
19-10 |
RFM732-M refractometer with latest integral 4” full colour display, robust switch membrane and USB connectivity. Supplied with instruction manual and certificate of conformity. |
19-20 |
RFM742-M refractometer with latest integral 4” full colour display, robust switch membrane and USB connectivity. Supplied with instruction manual and certificate of conformity. |
Specification |
RFM712-M |
RFM732-M |
RFM742-M |
Scales |
1.32 – 1.42 |
1.32 – 1.54 0-100 100 |
1.32 – 1.54 0-100 100 |
Resolution |
0.0001 |
0.0001 |
0.00001 0.01 |
Accuracy |
±0.0001 |
±0.0001 |
±0.00005 ±0.04 |
Precision (Reproducibility) |
± 0.00005 |
± 0.00005 |
± 0.00001 ± 0.01 |
User Scale Library |
20+ pre-programmed scales including HFCS (3), Sugar (4), Honey, NaCl, Wine Must (5), Urine SG (3), Glycol (2), Urea, FSII and more; plus customer programmable user scales via PC. |
20+ pre-programmed scales including HFCS (3), Sugar (4), Honey, NaCl, Wine Must (5), Urine SG (3), Glycol (2), Urea, FSII and more; plus customer programmable user scales via PC. |
20+ pre-programmed scales including HFCS (3), Sugar (4), Honey, NaCl, Wine Must (5), Urine SG (3), Glycol (2), Urea, FSII and more; plus customer programmable user scales via PC. |
Reading Time |
Minimum 4 seconds (optional time delay) |
Minimum 4 seconds (optional time delay) |
Minimum 4 seconds (optional time delay) |
Temperature Control |
None – Automatic Temperature Compensation (ATC) |
None – Automatic Temperature Compensation (ATC) |
None – Automatic Temperature Compensation (ATC) |
Temperature Compensation |
ICUMSA, AG, User, none |
ICUMSA, AG, User, none |
ICUMSA, AG, User, none |
Sample Temperature Range |
0-100 °C |
0-100 °C |
0-100 °C |
Measuring Temperature Range |
5-40 °C |
5-40 °C |
5-40 °C |
Temperature Sensor Accuracy |
± 0.03 °C |
± 0.03 °C |
± 0.03 °C |
Sample Temperature Stability |
± 0.05 °C |
± 0.05 °C |
± 0.05 °C |
Temperature Compensation |
|
|
|
Temperature Stability Checks |
Delay in seconds or none |
Delay in seconds or none |
Delay in seconds or none |
Sample Illumination |
Light Emitting Diode 589nm (100,000+ hours) |
Light Emitting Diode 589nm (100,000+ hours) |
Light Emitting Diode 589nm (100,000+ hours) |
Prism / Dish |
Artificial Sapphire / Stainless Steel 316 / PEEK (spill barrier) |
Artificial Sapphire / Stainless Steel 316 / PEEK (spill barrier) |
Artificial Sapphire / Stainless Steel 316 / PEEK (spill barrier) |
Prism Seal |
Silicon/Resin |
Silicon/Resin |
Silicon/Resin |
Interfaces |
1 x USB (A), 1 x USB (B), RS232 via USB adaptor (optional accessory) |
1 x USB (A), 1 x USB (B), RS232 via USB adaptor (optional accessory) |
1 x USB (A), 1 x USB (B), RS232 via USB adaptor (optional accessory) |
Power |
Instrument: 24 V DC, ±5%, External PSU: 100-240V, 50-60Hz (supplied) |
Instrument: 24 V DC, ±5%, External PSU: 100-240V, 50-60Hz (supplied) |
Instrument: 24 V DC, ±5%, External PSU: 100-240V, 50-60Hz (supplied) |
Humidity Range |
<90% RH (non-condensing) |
<90% RH (non-condensing) |
<90% RH (non-condensing) |